![]() SYNERGY CT PICC™ Line IR Kit Catalogue No. SYNERGY CT PICC™ Line Nurses Kit Catalogue No. SYNERGY CT PICC™ Line Basic Kit Catalogue No. The SYNERGY CT PICC™ line kit is available in Nursing, Basic, and Interventional Radiology long wire tray configurations. The SYNERGY power PICC’s low profile hub allows for easy suture or sutureless securement and improved patient comfort. The SYNERGY CT PICC™ line trays are organized with familiar industry components for clinician safety, including standard tearaway sheaths, echogenic safety needles, premium guide wires, and user-friendly procedural steps. Single-lumen 4Fr or double-lumen 5Fr power injectable peripherally inserted central catheters (PICCs) are not accurate for trans-pulmonary thermodilution (TPTD), since they overestimate cardiac index and other TPTD-derived parameters when compared with centrally inserted central catheters (CICCs) because of the smaller size of their lumen. ![]() Single, dual, and triple lumen power PICCs GuidewireĤ5cm Nitinol Straight Mandrel Guidewire with tungsten tip, 70cm Nitinol Straight Mandrel Guide Wire with tungsten tip, 130cm Nitinol Straight Mandrel Guide Wire with tungsten tip IntroducerĤ.5f x 10cm PTFE Tearaway, 5.5f x 10cm PTFE Tearaway, 6.5f x 10cm PTFE Tearaway Standardized Safety Trays and Components Maximum injection rates allow for the injection of contrast media at rates up to 5ml/sec for CECT Scans. Reverse Taperĭesigned to gently plug insertion site Injection Rating We were able to get a blood return using these techniques.SYNERGY CT PICC™ Line Kit Features MaterialĪ polyurethane construction with reverse taper technology helps reduce post-insertion bleeding while maintaining radiopacity and ensuring patient comfort. ![]() Have the patient take a deep breath and attempt to aspirate, you can also have the patient raise their arm above their head (if able). Have the patient perform the valsalva maneuver, this can help the catheter move away from the wall of the SVC. Sometimes the connectors can be the cause, if they have not been changed correctly. When you are troubleshooting “sluggish” catheters, take off the connector and attach your pre filled saline solution and attempt to aspirate from there. If your facility uses heparin to lock off the catheter, be sure to instill the heparin in each lumen. Thats exactly why a multiple lumen line is placed. Two incompatible medications can run simultaneously through a central line/PICC line. Be sure to flush pre and post infusion, flush well after lab sampling and always check for a blood return before use. For some reason when I worked in LTC, this myth of the 'red port' being for 'blood draws only' existed also. The largest lumen is used for lab sampling, but rotating lumen’s for infusion and lab sampling can help keep the line patent. When a patient has a multi lumen line, we need to care for each lumen separately. Health Lines single, dual, and triple lumen power PICC line kits are designed for nurses, doctors, and interventional radiologists of all experience levels. Research has shown that occluded catheters can contribute to CR-BSI’s (catheter related blood stream infections). We need to take the time to trouble shoot these lines and clear the catheter if necessary. When we look at best practice, we know that we should not use central lines that do not produce a blood return. “It infuses well, but unable to draw labs”. ![]() The nurse called and stated they were unable to get a blood return from the line. Dual Lumen Catheter, 4 Fr, with GuardIVa Antimicrobial Hemostatic IV Dressing, Probe Cover, and PinPoint GT Needle Guides. The patient was from a local skilled nursing facility and was being treated for an infection. Provena Power PICC Radiology Tray: 5/CS: Stock Allocated QTY: / Remaining QTY: / Allocation Reset Date: BARS3385335: PowerPICC Provena Catheter, Triple Lumen, 135 cm, 5 Fr: 5/CS. Catheter Size Maximum Flow Rate 3 F Single Lumen 1 mL/sec 4 F Dual Lumen 2.5 mL/sec Contraindications, Warnings and Precautions. Dual Power Injection Flow Rate 2. PICC with 5 mL/sec max flow rate designed for multiple infusion therapies as well as blood sampling. DISTRIBUTOR OPTIONS Distributors View all distributors. PowerPICC Nursing Power Injection PICC by CR Bard. PowerPICC SV Catheter 4 Fr Dual-lumen IR with 135 cm Nitinol Guidewire. For central venous pressure monitoring, it is recommended that a catheter lumen of 20 gauge or larger be used. PICC catheters PowerPICC SV Catheter, I.R. A patient came to the urgent care today with a triple lumen power PICC. sampling, power injection of contrast media, and allows for central venous pressure monitoring.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |